Frequently on heat stations the heat control is carried out using old well-known orifice method. Is it really good today?

 Let's give an example of real money saving on Kramatorsk heat station due to replacement of orifices with ultrasonic meters SVТU-10М of accuracy class 1.

Expenses

With orifice, ukr. hrivnas

With          SVTU-10М1, ukr. hrivnas

Comments

Equipment

30000

50000

The cost of orifice flow measuring set includes the cost of  chamber, orifice, sensor of variable pressure drop, pulse tubes with valves, two temperature sensors, project and calculations of flow measuring section, its certification in State Standard Committee

Installation and commissioning

20000

20000 

 

 

Annual service

12000

-

 

Recording

1000

-

For 2 recorders

Periodic calibration

700

100

Periodic calibration for SVTU-10М1 - 1 time in 4 years without dismantling. 

State verification

10000

100

Expenses on installation and dismantling

Total expenses on installation and equipment cost

50000

70000

The difference in expenses is 20000 ukr. hrivnas

Total expenses on annual operation

23700

200

SVTU-10М undergoes state verification 1 time in 4 years

Mentioned in the table cost of the complete set of SVTU really exceeds cost of the complete set of orifices, but total expenses for maintenance service and periodic calibration are considerably below. The difference makes 23500 ukr. hrivnas during the year. It means that initially it has been spent 20000 ukr. hrivnas more, but every year cost-savings are 23500 ukr. hrivnas for operation.
Hence, expenses will pay back less than in 1 year. As a result of application of new technical equipment is 14 % saving of the energy-carrier. Expenses for installation of new devices had been paid back for one month! By the way the expenses for repair of registering devices (recorders) are not considered.


Why should you waste your money buying a regular heat meter if there is SVTU-10М?

Have you evere thought that a standard heat meter after 3-5 and furthermore 10-12 years will hopelessly become outdated if it still will work by then? New 2 and 5-channel SEMPAL meters SVTU-10М are as much as possible equipped with the advanced built-in features which will please you during a minimum of 12 years of their operation. Many of our previous functions that have been developed ten years ago are just now starting to appear in many ordinary heat meters. Reliability of our equipment speaks for itself. Thousands of SVTU-10М many years function properly without replacements and additional operating costs.